High-Tensile Electric Fence Calculator
A 5-wire high-tensile electric fence 2,640 ft long needs 4 rolls of high-tensile wire (4,000 ft, 12.5 ga), 95 line posts at 25 ft and 26 wood brace posts. Estimated materials before the energizer: $2,993.
Results
Estimated material cost
$2,993
$1.13 per ft · 2,640 ft of high-tensile smooth wire
- High-tensile wire rolls
- 4
- 13,797 ft
- T-posts
- 95
- @ 25 ft
- Brace posts
- 26
- 5 assemblies
| Item | Qty | Cost |
|---|---|---|
| High-tensile wire rolls4,000 ft rolls x 5 wires · $175.00/roll | 4 | $700 |
| T-posts25 ft spacing · $7.25/post | 95 | $689 |
| Corner, brace & gate postsDouble H-braces, 6-8 in. x 8 ft wood · $30.00/post | 26 | $780 |
| Brace rails4 in. x 8 ft horizontal rails · $15.00/rail | 20 | $300 |
| Brace wire20 ft per brace, 9 ga · $0.10/ft | 400 ft | $40 |
| InsulatorsLine + corner/end insulators, one per wire · $0.35/ea | 505 | $177 |
| In-line strainersOne per wire per braced run · $4.50/ea | 25 | $113 |
| Gates12 ft tube gate · $195.00/gate | 1 | $195 |
| Total | $2,993 | |
Braces: 4 corner, 1 gate, 0 end, 0 in-line pull (double H). Excludes labor, concrete, tools, energizer and grounding.
How high-tensile quantities are calculated
High-tensile 12.5 ga wire comes in 4,000 ft rolls. Wire = fence length x wires x 1.05 / 4,000, rounded up. Because the wire is tensioned to about 250 lb per strand, posts can be 20-30 ft apart on level ground (closer on hills), and every brace should be a double H.
Gate openings are subtracted before wire is figured. Every corner, gate and fence end gets an H-brace, and long sides get extra in-line pull braces at the pull interval you set. Line posts fill each span between braces: span length / spacing, rounded up, minus one. With electric selected, each line post gets one insulator per wire and each corner, end and gate post gets one per wire; each wire also gets one in-line strainer per braced run. The energizer, ground rods and gate handles are not included.
Frequently asked questions
How far apart should high-tensile fence posts be?
20-30 ft on flat ground is typical, with line posts closer together over rises and dips. The default here is 25 ft.
How many rolls of high-tensile wire do I need?
Multiply fence length by the number of wires, add 5% and divide by 4,000 ft. A 5-wire fence 2,628 ft long takes 4 rolls.
How many insulators do I need for an electric fence?
One per hot wire on every line post, plus corner, end and gate insulators. For this example that is 505 insulators.
How far apart should fence brace assemblies be?
Brace every corner, gate post and fence end. On long straight runs, extension and NRCS guidance commonly calls for an in-line pull assembly about every 330 ft for hinge-joint woven wire, every 650-1,320 ft for barbed wire, and up to about 4,000 ft for high-tensile. Shorten the interval on rolling or rough ground.
Are the prices in this calculator accurate?
They are typical US farm-store prices for common sizes and change by region and season. Open the Prices panel and type what your local store charges; every total updates instantly.
Default prices are typical US farm-store prices as of November 2026. Quantities are planning estimates; check local codes, terrain and your supplier's roll lengths before ordering.