Greenhouse Heater Size Calculator (BTU)
A 20 x 48 ft double-poly hoop house kept at 50°F on a 0°F night loses about 74,869 BTU per hour, so it needs a heater of about 95,000 BTU/hr input at 80% efficiency — burning about 1.0 gallons of propane an hour at full output.
Results
Heater size
95,000 BTU/hr
input rating at 80% efficiency · heat loss 74,869 BTU/hr holding 50°F at 0°F outside
- Heat loss
- 74,869
- BTU/hr on the coldest night
- Propane per hour
- 1.01 gal
- $2.53/hr at full output
- Surface area
- 1,822 sq ft
- roof, sides and ends
- Volume
- 7,540 cu ft
- 0.75 air changes/hr
Where the heat goes
| Path | BTU/hr | Share |
|---|---|---|
| Through the covering | 63,774 | 85% |
| Air leaks | 5,655 | 8% |
| Foundation / perimeter | 5,440 | 7% |
| Total | 74,869 | 100% |
Heat loss by covering
| Covering | BTU/hr |
|---|---|
| Single poly | 111,312 |
| Double inflated poly | 74,869 |
| Double poly, IR-treated | 56,648 |
| Twin-wall polycarbonate | 65,759 |
| Single glass | 111,312 |
Heating checklist
- Use a vented heater rated for greenhouses; unvented combustion can injure plants (ethylene) and people (carbon monoxide).
- Add horizontal airflow fans so heat doesn't stratify at the peak.
- Seal gaps at doors, end walls and the base — air leaks are often the cheapest heat loss to fix — and keep the inflation fan running on double poly.
- Consider a backup heater or alarm; one cold night without heat can lose a crop.
Sized for the coldest night; average fuel use over a season is much lower. A thermal or energy curtain can cut night heat loss substantially.
How greenhouse heat loss is calculated
Heat loss (BTU/hr) = U-value x surface area x temperature difference, plus air leakage = 0.02 x volume x air changes per hour x temperature difference, plus heat lost along the foundation (UGA B792). U-values from ASAE EP406.4: about 1.1 for single poly or glass, 0.7 for double inflated poly and 0.5-0.6 for IR poly or twin-wall polycarbonate.
Surface area of a round-top hoop house is the arc (pi x width / 2 x length) plus two half-circle end walls. Divide heat loss by heater efficiency (about 80%) for the heater's input rating, and by the fuel's BTU content — 92,500 per gallon of propane, 100,000 per therm of natural gas (UMass) — for fuel per hour.
Frequently asked questions
How many BTU do I need to heat a greenhouse?
Surface area x U-value x (inside - outside temperature), plus air leaks. A 20 x 48 ft double-poly hoop house holding 50°F at 0°F needs roughly 75,000 BTU/hr of heat, or a 95,000 BTU input heater.
Does double poly save heat?
Yes. Double inflated poly (U about 0.7) loses about 35-40% less heat through the covering than single poly (U about 1.1).
Sources and assumptions
Use vented heaters approved for greenhouses and follow the manufacturer's clearance and venting instructions; unvented combustion can harm plants and people.